| TMQ.CV Series Table Top Pulsation Steam Vacuum Sterilizer      Application: With pressure steam as medium, it is used in sterilizing medical dressing, utensils, class A, Class B hollow lumen instruments, catheters, and waste in the operating room, clinic department, CSSD, biological laboratories and other healthcare sectors.   
 Main Features:  ●PLC control technology, colored touch screen; ●Affusion, pulse vacuum, heating, sterilizing, exhaust, vacuum drying whole process are automatically controlled by program; ●Dynamic pulsant vacuum exhaust air: Vacuum up to-0.08MPa, can exhaust steam in medical dressings, Class A hollow lumen instruments; ●Pulsation behind vacuum drying system to ensure parcels dry . ●High-performance built-in steam generator and steam-water separator devices, ensure quality steam,  without external steam source; ●With instruments, dressing, rubber and customized procedures for user's optional; ●With manually Bowie & Dick leaking and vacuum testing procedures; ●0.22μm HEPA filter can ensure the vacuum steam is amicrobic, to avoid further contamination; ●Dynamically LCD display temperature, pressure, time, sterilizing status, malfunction alarm; ●Equipped with maintenance reminding function. User-friendly maintenance equipment and replacement of wearing parts; ●Beep reminding when finishing; ●Mini printer is optional to real-time record the whole sterilizing process and malfunction informations.   Safety Protection:  ●Over-temperature protection: Over the setting temperature, system automatically cut off power and display alarm; ●Door safety interlock devices: Only the doors closed in place, sterilizers to start working procedures. If there is dangerous pressure in the chamber, the door can not be opened; ●Dual overpressure protection: Automatic releasing safety valve: If pressure is over design , safety valve will open to release; Overpressure automatic protection control: If pressure is over setting, safety valve will automatic release and display alarm; ●Anti-dry alarm: below the water level, automatically cut off the heating power, and display alarm information; ● Electronic circuit safety devices: AC main circuit with a short-circuit protection, over-voltage DC control circuits with overload protection.   Main Technical Parameters:  Designed Pressure: -0.1/0.28MPa           Max. Working Pressure: 0.23MPa           Pressure Display Precision: ± 0.1KPa Sterilization Temperature Range: 105℃~136℃  Temperature Display Precision: ±0.1℃ Temperature uniformity: ㄑ±0.5℃   Chamber Material: SUS304 stainless steel   
 |