USAGE |
|
Product Introduction ¡öXG2.SC series of sterilizer, with ethylene oxide as sterilizing medium, is mainly used in the sterilization of products unable to stand for heat and moisture such like medical polymer materials, medical electronic instruments and optical instruments, Chinese medication and etc, equipped with automatic functions of EO entry control, time control, temperature control, moisture control and ventilation. ¡öThey could kill wide-pedigree bacterium, strong penetrability (including cloth, canton, polythene film), no damage to and easy storage for the sterilized goods. |
| |
Specifications |
|
Technical Parameter Chamber Size: 1200¡Á610¡Á910mm Chamber Volume: 0.6cubic meters Packing Dimensions: 1800¡Á1300¡Á2300mm Control Power: AC220V/50Hz 0.5 kw Dynamic Power: 380V Heater power: 15kw Vacuum pump power: 2.35kw Max Water Consumption: 160kg/cycle The whole sterilization period: 6-10h |
| |
Characteristics |
|
Performance characteristic ¡öDouble-coated cubic body construct, strict quality and security standard ¡öMulti-grade interlock sealing door, operation by mistake can be avoided efficiently. ¡öWhole procedure is under the control of high-reliable microcomputer. Abnormal signals are monitored and controlled in time. ¡öWorld-branded fittings keep the sterilizers advanced and long-term smooth operating. ¡öNegative pressure sterilizing technics of the whole process, eliminates the possibility of leakage of ethylene oxide gas. ¡öSpecial quantitative small package of ethylene oxide, even and reliable of the sterilizing concentration. ¡öSeveral cycles of vacuum pulse damping, the sterilizing temperature is controlled efficiently. ¡öMulti-parameters can be printed and recorded in time during the sterilizing process. ¡öPassword of operator can prevent operation by others. |
| |
|
|
Configuration ¡öThe inner shell and door board are made of 304 stainless steel and polished. ¡öSlopy pneumatic valve from GEMU, Germany. ¡öGermany burkert Steam entry electromagnetic valve. ¡öGermany nash_elmo Vaccum Pump. ¡öGRUNDFOS circulation pump from Danmark. ¡öSpecial control system ¡öThe tiny printer records date and parameters in the course of sterilization |
| |
|
|
Standard on the product ¡öYZB/0116-2003 |
| |
|
|
Installation requirements ¡öSteam Source Pressure£º0.3¡«0.5Mpa ¡öWater Source Pressure£º0.15¡«0.3Mpa ¡öCompressed Air Source Pressure:0.5¡«0.7Mpa |
|
|
|
|
|
| |
|
The product information will probably be updated without notice, if that happens, please refer to the latest technical material. |
|
|
|
|