SEARCH:
      
   
Tabletop Steam Autoclaves
Portable Stainless Steel Steam Autoclaves
Vertical Pressure Steam Autoclaves
Floor Type Steam Sterilizers
Horizontal Sterilizers
Manual Door Pulsant Vacuum Sterilizers
Mechanized Door Pulsant Vacuum Sterilizers
Cassette Autoclave Sterilizers
EO Gas Sterilizers
Transfusion Water Bath(Ventilated) Sterilizers
Rapid Cooling Injection Sterilizers
Ampoule Sterilizers
Chinese Powder Medicine Drying Sterilizers
Medical Drying Cabinets
Hot Air Sterilizers
Dynamic air sterliizers
Foodstuffs , Meats, Fruits, Vegetables Sterilizers
Clothes or tools sterilizers
Plasma Sterilizers
Low-Temperature Formaldehyde Steam Sterilizers
Ultraviolet Lamp Trolleys
Washer Disinfectors
Small Ultrasonic Cleaners
Large Ultrasonic Cleaners
OEM Ultrasonic Cleaners
Water Distillers
Medical Sterilization & Cleaning Accessory Equipments
Infrared inoculation sterilizers
Glass Bead Sterilizers
Decolorization, transfer, universal shakers
Mixer Series
Oscillator Series
UV Analyzers
Mini Centrifuges
Constant Temperature Incubators
Rotating Shaker Incubators
Mini Vacuum Pumps
Magnetic Stirrers
Pipettes

Products

     Medical Sterilization & Cleaning Accessory Equipments    Medical Disinfecting Packages 
Heat-sealing Conneccting Pouches

The usage illustration of the heat-sealing flat reels


The usage:
1. To choose the proper sizes pouches as per the size the equipment¡¯s to be sterilized. And then put the clean and dry equipment into the pouches. The equipment should be less than 3/4 of the sizes of the pouches to ensure the seal successfully and avoid the break of the pouches.
2. Make the acuate edge of the equipment to be contrary to the peeling direction, during putting the acuate equipment in to the pouches.
3. Seal the pouches with the heat-seal machine,marking the detailed information such as the sterilization date,the equipment name and the usage etc.at the same time.pls note to leave 1-2.5 cm to ensure peel characteristics.
4. Put the film side of the pouches against the heat bar of the heat-seal machine,the valid temperature should be 200-230oC,the valid pressure should be 0.15kg/cm2,and the valid time should be 4--6 seconds.
5. Put the closed pouches into the steam clave or ETO sterilizer, according to the rule to let the pouches¡¯ paper side against paper side, and then do the sterilization as per the normal methods.
6. To identify the situation of indicator¡¯s color change: if sterilization proceeded, it will turn black from initial blue based on steam sterilization method, and will turn brown from initial pink based on the ETO sterilization method.
7. Store the sterilized pouches dry, clean and dark-light place.
8. Tear the pouches as per the peeling direction and put the sterilized equipment out.


the notes:
1.The valid period will be 6 months on the steam sterilization method basis.And will be 24 months on the ETO sterilization methods basis.
2. Do not use if the pack is damaged.

SORT
NO.
TYPE
GOODS NO.
SIZE WXL (mm)
SIZE OF OVER-WRAPPED
SIZE OF BOX
SIZE OF CASRTON
(G.W./CARTON)
(M3)/CARTON
PIE/CARTON
ROLL/CARTON
BOX/CARTON
S
5201
S
52038092
38X118
190X118
120X195X40
430X300X260
18.32
0.033
200
28
5600
5202
S-1
52050120
50X150
250X150
153X255X40
480X310X260
22.47
0.038
200
21
4200
The product information will probably be updated without notice, if that happens, please refer to the latest technical material.
    



Contact Information
Yongfeng Enterprise Co., Ltd.
Add: No.1, Lane 110, Shengfeng Road, Ningbo, 315010, China
Tel:  86-574-87255354
Fax: 86-574-87125894
E-mail: sales@yongfeng-medical.com  
Web Site: http://www.yongfeng-medical.com  

Copyright 2024, All rights reserved. Design By HiSupplier Online Inc.
Browse Keywords By Alphabet: A B C D E F G H I J K L M N O P Q I S T U V W X Y Z 0-9